- Language: en
Mixed error model fitted to mixed error data, but with incorrect variance definition¶
[Generated automatically as a Fitting summary]
Inputs¶
Description¶
Name: | pa_gen_pa_fit_badvar |
---|---|
Title: | Mixed error model fitted to mixed error data, but with incorrect variance definition |
Author: | Wright Dose Ltd |
Abstract: |
One compartment model with a depot leading to a central compartment
This model contains both proportional and additive error, but erroneously sums the standard deviations.
Keywords: | one compartment model; dep_one_cmp_cl; proportional and additive error |
---|---|
Input Script: | pa_gen_pa_fit_badvar.pyml |
Input Data: | synthetic_data.csv |
Diagram: |
Initial fixed effect estimates¶
f[PNOISE_STD] = 0.5000
f[ANOISE_STD] = 0.2500
Outputs¶
Final fitted fixed effects¶
f[PNOISE_STD] = 0.0699
f[ANOISE_STD] = 0.0400
Fitted parameter .csv files¶
Fixed Effects: | fx_params.csv (fit) |
---|---|
Random Effects: | rx_params.csv (fit) |
Model params: | mx_params.csv (fit) |
State values: | sx_params.csv (fit) |
Predictions: | px_params.csv (fit) |