One Compartment Model with Absorption estimating KA, V and CL¶
[Generated automatically as a Tutorial summary]
Model Description¶
Name: | d1cmp_ka_v_cl_stderr |
---|---|
Title: | One Compartment Model with Absorption estimating KA, V and CL |
Author: | PoPy for PK/PD |
Abstract: |
One Compartment Model with Absorption compartment with rate (KA).
Elimination rate parametrised by clearance (CL)
and volume of distribution (V).
Model specification uses incremental flows
Keywords: | dep_one_cmp_cl; one compartment model |
---|---|
Input Script: | d1cmp_ka_v_cl_stderr.pyml |
Diagram: |
Comparison¶
True objective value¶
-42.7757
Final fitted objective value¶
-44.7678
Compare Main f[X]¶
Name | Initial | Fitted | True | Abs. Error | Prop. Error |
---|---|---|---|---|---|
f[KA] | 0.3 | 0.274 | 0.3 | 2.62e-02 | 8.72% |
f[V] | 20 | 18 | 20 | 2.00e+00 | 10.01% |
f[CL] | 3 | 3.24 | 3 | 2.39e-01 | 7.96% |
Compare Noise f[X]¶
No Noise f[X] values to compare.
Compare Variance f[X]¶
No Variance f[X] values to compare.
Outputs¶
Fitted f[X] values (after fitting)¶
f[KA] = 0.2738
f[V] = 17.9983
f[CL] = 3.2389
Generated data .csv file¶
Synthetic Data: | synthetic_data.csv |
---|