• Language: en

One Compartment Model with Absorption and Inter-occasion Variance f[CL_isv]=0.2

[Generated automatically as a Tutorial summary]

Inputs

Description

Name:dep_one_cmp_cl_iov
Title:One Compartment Model with Absorption and Inter-occasion Variance f[CL_isv]=0.2
Author:Wright Dose Ltd
Abstract:
Population one Compartment Model with Absorption and Inter-occasion Variance
Keywords:one compartment model; dep_one_cmp_cl; iov
Input Script:dep_one_cmp_cl_iov.pyml
Diagram:

True f[X] values

f[KA] = 0.3000
f[CL] = 3.0000
f[V] = 20.0000
f[PNOISE_STD] = 0.1000
f[ANOISE_STD] = 0.0500
f[CL_isv] = 0.2000
f[CL_iov] = 0.1000

Starting f[X] values

f[KA] = 0.5000
f[CL] = 1.0000
f[V] = 15.0000
f[PNOISE_STD] = 0.2000
f[ANOISE_STD] = 0.2000
f[CL_isv] = 0.0100
f[CL_iov] = 0.0100

Outputs

Fitted f[X] values

f[KA] = 1.0000
f[CL] = 2.2292
f[V] = 20.7548
f[PNOISE_STD] = 0.2102
f[ANOISE_STD] = 0.0517
f[CL_isv] = 0.0703
f[CL_iov] = 0.0871

Plots

Dense comp plots

Alternatively see All dense_comp graph plots

Comparison

True objective value

-344.3939

Final fitted objective value

-276.4374

Compare Main f[X]

Name Initial Fitted True Prop. Error Abs. Error
f[KA] 0.5 1 0.3 233.33% 7.00e-01
f[CL] 1 2.23 3 25.69% 7.71e-01
f[V] 15 20.8 20 3.77% 7.55e-01

Compare Noise f[X]

Name Initial Fitted True Prop. Error Abs. Error
f[PNOISE_STD] 0.2 0.21 0.1 110.19% 1.10e-01
f[ANOISE_STD] 0.2 0.0517 0.05 3.41% 1.70e-03

Compare Variance f[X]

Name Initial Fitted True Prop. Error Abs. Error
f[CL_isv] 0.01 0.0703 0.2 64.83% 1.30e-01
f[CL_iov] 0.01 0.0871 0.1 12.91% 1.29e-02
Back to Top