• Language: en

One Compartment Model with Absorption and Inter-occasion Variance f[CL_isv]=0.2

[Generated automatically as a Tutorial summary]

Inputs

Description

Name:dep_one_cmp_cl_iov
Title:One Compartment Model with Absorption and Inter-occasion Variance f[CL_isv]=0.2
Author:Wright Dose Ltd
Abstract:
Population one Compartment Model with Absorption and Inter-occasion Variance
Keywords:one compartment model; dep_one_cmp_cl; iov
Input Script:dep_one_cmp_cl_iov.pyml
Diagram:

True f[X] values

f[KA] = 0.3000
f[CL] = 3.0000
f[V] = 20.0000
f[PNOISE_STD] = 0.1000
f[ANOISE_STD] = 0.0500
f[CL_isv] = 0.2000
f[CL_iov] = 0.1000

Starting f[X] values

f[KA] = 0.5000
f[CL] = 1.0000
f[V] = 15.0000
f[PNOISE_STD] = 0.2000
f[ANOISE_STD] = 0.2000
f[CL_isv] = 0.0100
f[CL_iov] = 0.0100

Outputs

Fitted f[X] values

f[KA] = 1.0000
f[CL] = 2.2364
f[V] = 20.9615
f[PNOISE_STD] = 0.2091
f[ANOISE_STD] = 0.0516
f[CL_isv] = 0.0732
f[CL_iov] = 0.0937

Plots

Dense comp plots

Alternatively see All dense_comp graph plots

Comparison

True objective value

-344.3937

Final fitted objective value

-276.3471

Compare Main f[X]

Name Initial Fitted True Prop. Error Abs. Error
f[KA] 0.5 1 0.3 233.33% 7.00e-01
f[CL] 1 2.24 3 25.45% 7.64e-01
f[V] 15 21 20 4.81% 9.61e-01

Compare Noise f[X]

Name Initial Fitted True Prop. Error Abs. Error
f[PNOISE_STD] 0.2 0.209 0.1 109.06% 1.09e-01
f[ANOISE_STD] 0.2 0.0516 0.05 3.22% 1.61e-03

Compare Variance f[X]

Name Initial Fitted True Prop. Error Abs. Error
f[CL_isv] 0.01 0.0732 0.2 63.41% 1.27e-01
f[CL_iov] 0.01 0.0937 0.1 6.27% 6.27e-03
Back to Top